The LINK 5020 Sensor Interface is a truly versatile die protection and process monitoring interface system to simplify the quick connection of up to 16 sensors of diverse types to die protection logic units.

5020 Sensor Interface
  1. OmniLink 5000 Die Protection Logic Module. Up to 16 sensor outputs to die protection logic.
  2. LED indicators show status of each input sensor.
  3. Alternative use of binding posts rather than receptacles for inputs 1-4 allows quick single wire connection of probes and other grounding type mechanical sensors.
  4. Power and input receptacles to plug in electronic sensors with either npn or pnp outputs for inputs 1-8.
    • Proximity Sensors
    • Optical Sensors
    • Fiber Optic Sensors
    • LINK Infrared Parts Detectors
    Widely available "Micro DC" style connectors allow the use of sensors with standard molded cables with "Micro DC" plugs for use of field wireable "Micro DC" plugs to terminate sensor cables.
  5. User's die mounted sensor box with receptacle.
  6. Quick Connect Receptacle for up to 8 inputs from sensor dock or up to 16 inputs from user's die mounted sensor box with receptacle.
  7. Optional sensor dock can be press or die mounted to provide 8 additional "Mirco" receptacles for inputs 9-16.
  8. The LINK 5020 power supply provides 1A at 24V.
5020 Sensor Interface Specifications
Sensors Accomodated:  
  • Sensors with npn pnp open collector outputs with no LED indicators.
  • Sensors with npn pnp open collector outputs with LED indicators that are not driven in parallel with the load.
  • Probes and other mechanical sensors.
  • LINK 3040 and 3080 Infrared Parts Detectors
Sensor Interface Power Supply: 24VDC @ 1 Amp MAX output. Input power 95-140VAC 50/60 Hz, 0.3A.
Sensor Inputs: 16 Max Total
  • 8 Max through individual connectors 1-8 on 5020 enclosure.
  • 16 Max through Quick Connect receptacle on 5020 enclosure (each sensor connection to indivdual connectors 1-8 on the 5020 enclosure reduces by 1 the connections available through the Quick Connect receptacle).
Sensor Connections Provided: Signal (N/O), Power and Common for individualfor individual and Quick Connect receptacles.
Signal only if binding posts are used for inputs 1-4.
Sensor Threshold On-State Voltage Requirements: On-State (actuated) sensor output voltage must be <5 volts for npn and mechanical sensors and >19 volts for pnp sensors. Multiple sensors may be used in series or parallel to one input if their combined outputs do not violate the on-state threshold voltage requirements. When binding posts are used as inputs on inputs 1-4 probes/mechanical sensors a switch can select high impedance or low impedance for each input.
Enclosure 10.2"H x 6.2"W x 4.15"D (259 mm x157.5 mm x 105.4 mm).
Receptacles: Individual recetacles: 4 socket "Micro DC" style (multiple sources). Quick Connect recetacle : 19 socket Amphenol 97-3102A-22-14S. Other Quick Connect receptacles available at added cost and lead time.
Plugs For Receptacles: Plugs for individual receptacles: 4 pin "Micro DC" (multiple sources). Quick Connect plugs: 19 pin Amphenol 97-3106A-22-14S (straight) or 97-3108A-22-14S (right angle). Other Quick Connect plugs available at added cost and lead time.